Browse Publications Technical Papers 2002-01-2535
2002-07-15

A Rapid Method for Determining Biocide Concentration in a Spacecraft Water Supply 2002-01-2535

Monitoring and maintaining biocide concentrations is vital for assuring safe drinking water both in ground and spacecraft applications. Currently, there are no available methods to measure biocide concentrations (i.e., silver ion or iodine) on-orbit. Sensitive, rapid, simple colorimetric methods for the determination of silver(I) and iodine are described. The apparatus consists of a 13-mm extraction disk (Empore® membrane) impregnated with a colorimetric reagent and placed in a plastic filter holder. A Luer tip syringe containing the aqueous sample is attached to the holder and 10 mL of sample is forced through the disk in ∼30 s. Silver(I) is retained by a disk impregnated with 5-(p-dimethylaminobenzylidene)-rhodanine (DMABR), and iodine is retained as a yellow complex on a membrane impregnated with polyvinylpyrrolidone (PVP). After passage of a water sample, the colorimetric response generated by the interaction between analyte and reagent is measured by use of a hand-held, commercial reflectance spectrophotometer. This simple solid-phase extraction (SPE) method gives a high concentration factor. The sensitivity for both measurements is excellent: 0.005 mg/L for Ag(I) and 0.1 mg/L for I2. Furthermore, the methodology minimizes sample handling and potential contamination events, produces only a small volume of waste, and requires only ∼60 s for completion. Details related to membrane impregnation, calibration, and interferences are also presented. The method was successfully tested on the ground using samples of actual Space Shuttle and International Space Station drinking water.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

A Matrix-Based Porous Tube Water and Nutrient Delivery System

921390

View Details

JOURNAL ARTICLE

International Space Station United States Orbital Segment Oxygen Generation System On-orbit Operational Experience

2008-01-1962

View Details

TECHNICAL PAPER

Test Results of Reflux-Cooled Electromechanical Actuator

942176

View Details

X