Browse Publications Technical Papers 2005-01-2977
2005-07-11

Effect of Local Hand Thermal Insulation on Total and Local Comfort Under Different Levels of Body Heat Deficit 2005-01-2977

Introduction: There are contradictory opinions regarding the contribution of local hand thermal insulation to support local and total comfort during extravehicular activity (EVA). Instead of a local correction by means of thermal insulation on the periphery of the body to prevent heat dissipation, it may be optimal to prevent heat dissipation from the body core. To examine such a concept, the effects of different insulation levels on the left and right hands on the heat flux and temperature mosaic on the hands was measured. These variables were assessed in relation to the level of heat deficit forming in the core organs and tissues. Methods: Six subjects (4 males, 2 females) were donned in a liquid cooling/warming garment (LCWG) that totally covered the body surface except for the face. Participants wore the Phase VI space gloves including the entire micrometeoroid garment (TMG) on the left hand, and the glove without the TMG on the right hand. The experimental sessions consisted of three stages with inlet water temperatures as follows: Stage 1 baseline - 33°C; Stage 2 cooling - 20°C; Stage 3 warming - 45°C. Skin temperature was measured on the fingers, dorsal part of the hand; rectal temperature was also measured. Results: In Stage 2 cooling, there was a 3.5±0.3 kcal/min heat deficit reflected in the decreasing finger (Tfing) and hand temperature (Tha); there was no significant difference in temperature between the two hands. On both hands, Tfing decreased from 33.4±1.2°C (Stage 1) to 27.8±1.5°C (Stage 2), while Tha decreased from 32±1.2°C to 31.8±0.6°C. In Stage 1, there was a 1.4° C temperature difference between the dorsal part of the hand (32°C) and the distal phalanx of the 4th finger (33.4°). This difference increased to 4° at the end of the Stage 2 cooling (Tfing 27.8°; Tha 31.8°). Conclusions: Under the development of a general heat deficit/surplus in the body, there was no influence of differing insulation on each hand. The primary influence on local hand and total body thermal status is not distal thermal insulation, but the forming total deficit of heat in the body core organs.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Thermal Analysis of Lightweight Liquid Cooling Garments Using Highly Conductive Materials

2005-01-2972

View Details

TECHNICAL PAPER

Evaluation of 6 Different Correlations for the Flow Friction Factor of Stirling Engine Regenerators

1999-01-2456

View Details

TECHNICAL PAPER

Experimental Study and Thermal Modeling of an Automobile Driver with a Heated and Ventilated Seat

2003-01-2215

View Details

X