End-To-End Protection for SIL3 Requirements in a FlexRay Communication System 2008-01-0112
This paper proposes end-to-end protection mechanisms to be added to a generic FlexRay network in order to achieve fault detection and integrity levels sufficient for a SIL3 fail safe communication system. The mechanisms are derived from the random hardware failure modes to be considered for communication controllers according to IEC 61508. Mechanisms provided by the FlexRay protocol are pointed out. Additional features necessary to fulfil the requirements are discussed. It is shown how to calculate the failure rate probabilities of the CRC used as a safety code with respect to EN 50159.
Citation: Gstöttenbauer, B., Stöger, G., Fazely, S., Kalhammer, M. et al., "End-To-End Protection for SIL3 Requirements in a FlexRay Communication System," SAE Technical Paper 2008-01-0112, 2008, https://doi.org/10.4271/2008-01-0112. Download Citation
Author(s):
Bernhard Gstöttenbauer, Georg Stöger, Siamaek Fazely, Manfred Kalhammer, Sven Schachtner
Affiliated:
TTTech Automotive GmbH, AUDI AG
Pages: 8
Event:
SAE World Congress & Exhibition
ISSN:
0148-7191
e-ISSN:
2688-3627
Also in:
Safety-Critical Systems, 2008-SP-2173
Related Topics:
Communication systems
Failure modes and effects analysis
Fault detection
Hardware
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.