Browse Publications Technical Papers 2015-01-1658
2015-04-14

Simultaneous In-Cylinder Surface Temperature Measurements with Thermocouple, Laser-induced Phosphorescence, and Dual Wavelength Infrared Diagnostic Techniques in an Optical Engine 2015-01-1658

As engine efficiency targets continue to rise, additional improvements must consider reduction of heat transfer losses. The development of advanced heat transfer models and realistic boundary conditions for simulation based engine design both require accurate in-cylinder wall temperature measurements. A novel dual wavelength infrared diagnostic has been developed to measure in-cylinder surface temperatures with high temporal resolution. The diagnostic has the capability to measure low amplitude, high frequency temperature variations, such as those occurring during the gas exchange process. The dual wavelength ratio method has the benefit of correcting for background scattering reflections and the emission from the optical window itself. The assumption that background effects are relatively constant during an engine cycle is shown to be valid over a range of intake conditions during motoring.
The diagnostic was validated by simultaneous in-cylinder surface temperature measurements during motored engine conditions, with three independent measurement techniques: thermocouple, laser-induced phosphorescence, and the dual wavelength infrared diagnostic. All of the techniques were applied at different intake conditions. However, characteristic differences are observed between the measurements of each technique.
Heat flux is obtained from both the thermocouple and infrared measurements by application of Fourier's law. The infrared measurements show that time-average and transient terms increase as intake pressure increases at constant intake gas temperature, and only that time-average term increases as intake gas temperature increases while charge density is constant. Average cycle thermocouple, laser induced phosphorescence and IR diagnostic temperature measurements agree within 12 °C for all conditions tested. The temperature range determined by the IR diagnostic is greater than that obtained from the thermocouple, but less than that from the phosphorescence technique. Peak dynamic heat flux determined from the IR diagnostic is nearly twice as high as the flux determined from the thermocouple. An examination of the measured temperatures in the frequency domain shows that the IR diagnostic has greater contribution by higher frequency terms, illustrating the fast response advantage of the technique.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

2D Mapping and Quantification of the In-Cylinder Air/Fuel-Ratio in a GDI Engine by Means of LIF and Comparison to Simultaneous Results from 1D Raman Measurements

2001-01-1977

View Details

JOURNAL ARTICLE

Optimizing Precision and Accuracy of Quantitative PLIF of Acetone as a Tracer for Hydrogen Fuel

2009-01-1534

View Details

TECHNICAL PAPER

Direct Injection of Variable Gasoline/Methanol Mixtures: Injection and Spray Characteristics

2001-01-0966

View Details

X