CRC Investigation of Diesel Smoke Measurement (Report of Smokemeter Group of the Diesel Vehicle Fuel, Lubricant and Equipment Research Committee of the Coordinating Research Council, Inc.) 640105
Cooperative work on diesel smoke measurement has been conducted for more than twenty years. Results of this work have shown that smoke measurement can be reasonably exact if conducted properly. Application of experimental results and the experience of the Smokemeter Group of the Coordinating Research Council (CRC) are presented as the state-of-the-art, outlining techniques and guides necessary for acceptable smoke measurement. Information is provided on choice of smokemeter type, smokemeter operation, sampling, expression of data, and visual rating. The CRC Smokemeter Group recommends that this information be used as a basis for general work and communication in diesel smoke measurement.
Citation: Durant, J., "CRC Investigation of Diesel Smoke Measurement (Report of Smokemeter Group of the Diesel Vehicle Fuel, Lubricant and Equipment Research Committee of the Coordinating Research Council, Inc.)," SAE Technical Paper 640105, 1964, https://doi.org/10.4271/640105. Download Citation
Author(s):
J. B. Durant
Affiliated:
American Oil Co
Pages: 11
Event:
SAE World Congress & Exhibition
ISSN:
0148-7191
e-ISSN:
2688-3627
Related Topics:
Research and development
Lubricants
Tools and equipment
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.
Learn More »