1969-02-01

Boiling Point Precision Data for SAE Brake Fluids 690223

The precision of measuring the boiling point of high boiling brake fluids was determined by 18 laboratories on three brake fluid samples (374, 450, and 550 F). Tests were made using both a heating mantle and an electric heater.
Reproducibility on the 374 and 450 F fluids. Two results (each the average of duplicates), obtained by analysts in different laboratories, should be considered suspect (95% confidence level) if they differ by more than 9 F.
Reproducibility on the 550 fluid. Two results (each the average of duplicates), obtained by analysts in different laboratories, should be considered suspect (95% confidence level) if they differ by more than 19 F.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.