Effects of DPF Volume on Thermal Shock Failures during Regeneration 890173

Application of ceramic honeycomb wall-flow type diesel particulate filters (DPF) to heavy duty vehicles requires a large volume filter. Heavy duty vehicles produce a large volume exhaust gas, and pressure drop in the exhaust system must be maintained to a certain level. In addition, the filters must be designed to resist fracture from thermal stresses during regeneration. This is particularly important in heavy duty vehicles because of these extended mileage requirements.
These studies of the effects of DPF volume on thermal shock resistance during regeneration reveal that the maximum failure temperatures are lower as DPF volume is increased, still maintaining 950°C maximum temperature with 12 ℓ volume and 9″D × 12″L size large DPF.
Some thermal stress analyses with temperature profiles and finite element analysis were conducted on four different volume DPF during regeneration.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Analyses of Thermal Shock Failure on Large Volume DPF

900113

View Details

TECHNICAL PAPER

Heavy Duty Diesel After-Treatment System Analysis Based Design: Fluid, Thermal and Structural Considerations

2009-01-0624

View Details

TECHNICAL PAPER

Numerical Simulations and Experimental Validation of an SCR System for Ultra Low NOx Applications

2021-01-1222

View Details

X