1992-07-01

Effects of Air Bubble Contamination in Recirculating Water Loop 921282

Long life in space of the Columbus recirculating water transport loop indicates probability that air bubble contamination will inadvertently be added to the loop during service revision, or repair procedures. This paper describes the results of tests run to simulate the effects of bubble contamination on the operation in zero gravity of a recirculating water loop.
All major components of the loop were installed with their water inlet and outlet connections at the top to prevent bubbles from being separated and stored in the components. In this way the bubbles were encouraged to recirculate in the loop in the manner expected in space with zero g operation. Maximum air injection without adverse pump operation was determined.
A brief trade-off of prospective bubble trap concepts is presented, and a preliminary investigation of a hydrophobic membrane bubble separator for this application is discussed.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

The Effects of Alternative Biological Primary Processing Approaches on the Efficiency of an Integrated Water Processing System

2005-01-2980

View Details

TECHNICAL PAPER

Experience in Development and Long-term Operation of Mir's System for Oxygen Generation by Electrolysis

2000-01-2356

View Details

TECHNICAL PAPER

Study of Air Revitalization System for space station

891576

View Details

X