Thermal Conditioning Unit

Paper #:
  • 941284

Published:
  • 1994-06-01
Citation:
Madorell, X., Llamas, X., Pastor, M., and Tomás, A., "Thermal Conditioning Unit," SAE Technical Paper 941284, 1994, https://doi.org/10.4271/941284.
Pages:
9
Abstract:
This document describes a Thermal Conditioning Unit (TCU) concept that can be used to keep samples at any selected temperature between -20 °C and 50 °C in space environment.The adaptation to the two mission scenarios (Biorack in Spacelab IML-2 and MIR station) where the concept has been used is described, providing design solutions, performances and test results.Proposals for new future configurations are also presented.Safety and reliability aspects are assessed.