Physics and Measurement of Early Wire Insulation Chafing 2008-01-2931

This paper discusses the physics of development of electrical defects as the result of wire chafing, and how this can be used to extend the prognostics capability of GE's Smartwire Diagnostic System (SWDS). Chafing, a top symptom of failures (37% in one study [4]) is frequently caused by mechanical vibration of wiring harnesses, which are often strapped to the aircraft structure or run through other types of cable supports (trays, bends, etc.); ambient aircraft structural vibrations are a primary mechanical driver of long term chafing.
The US Navy's charter to reduce annual wiring maintenance expenditures by an estimated $57 million provided the driving force for this research effort. No system is available today that can detect and locate a wire insulation chafe without the user disconnecting the wires or passing a high voltage through them. The overall objective of SWDS is to address this gap in wire health monitoring. One of the main goals of SWDS is to detect small wire chafes before they can cause catastrophic electrical failures.
The SWDS consists of GE flex sensors, a high-speed data acquisition system and advanced algorithms. In this paper we assess the capability of the sensor to assess various stages of insulation damage, including small but developing defects. The ability to detect very early stages of insulation damage prior to conventionally detected electrical failure is termed “prognostics”. In this paper we will also summarize the present technological barriers to effective and reliable detection and diagnosis of early wire insulation chafing and will discuss the future of prognostic system development for wire chafing in aircraft.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
We also recommend:
TECHNICAL PAPER

Carrier Injection Positive and Negative Sequence Impedances for Wound Field Synchronous Starter/Generators

2004-01-3186

View Details

TECHNICAL PAPER

Interfacing Power Line Communications to Airborne Vehicles: A Technical Review

2008-01-2879

View Details

TECHNICAL PAPER

Energy Analysis of Electromechanical Actuator under Simulated Aircraft Primary Flight Control Surface Load

2014-01-2182

View Details

X