Test Results of the PLUGLESS™ Inductive Charging System from Evatran Group, Inc. 2014-01-1824
Laboratory testing is conducted on a wireless charging system by the Idaho National Laboratory in support of the U.S. Department of Energy's Advanced Vehicle Testing Activity. System efficiency and magnetic and electric field strength are measured during wireless charger operation over a wide range of conditions, including coil gap, offset alignment, and power transfer rate. Component surface temperatures are monitored at a full-power charge rate. The PLUGLESS™ inductive charging system from the Evatran Group, Inc. is tested in a laboratory setting and results are detailed.
Citation: Carlson, R. and Normann, B., "Test Results of the PLUGLESS™ Inductive Charging System from Evatran Group, Inc.," SAE Int. J. Alt. Power. 3(1):64-71, 2014, https://doi.org/10.4271/2014-01-1824. Download Citation
Author(s):
Richard W. Carlson, Brian Normann
Affiliated:
Idaho National Lab., Evatran Group Inc.
Pages: 8
Event:
SAE 2014 World Congress & Exhibition
ISSN:
2167-4191
e-ISSN:
2167-4205
Also in:
SAE International Journal of Alternative Powertrains-V123-8EJ, SAE International Journal of Alternative Powertrains-V123-8
Related Topics:
Magnetic materials
SAE MOBILUS