1957-01-01

LABORATORY FATIGUE TESTING OF GEARS 570037

IN the first part of this paper, Mr. Halgren discusses modified 4-square testing of gears in relation to service performance, field tests, and other accelerated laboratory test methods. It contains a short description and photographs of nine different designs of modified 4-square gear testing machines now in use.
Description of machines includes comments on mounting rigidity, mass-elastic system, load application, measurement and control, shut-off devices, and lubrication.
Mr. Wulpi discusses single-tooth fatigue testing which is used to measure the bending strength of gear teeth. One tooth at a time is tested in the manner of a cantilever beam. By successive testing, many teeth of the same gear may be tested, and endurance limits obtained if desired.
Results of these tests show that it is possible to determine clearly the effect of various metallurgical factors, such as material, heat-treatment, or surface-finishing treatment upon the bending-fatigue strength of gear teeth.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Impact Fatigue Resistance of Commonly Used Gear Steels

710277

View Details

TECHNICAL PAPER

Crack Initiation and Propagation in RCF – A New Approach to Understanding Pitting Failure of Highly Loaded Gears

2006-01-0383

View Details

TECHNICAL PAPER

A Study of Three Layer Copper-Lead Bearings Without Nickel Barrier

970214

View Details

X