1972-02-01

An Analysis of Automatic Transmission Clutch-Plate Temperatures 720287

Automatic transmission clutch failures and rapid oxidation of the transmission fluid have sometimes been attributed to high temperatures in the clutch pack. For the purpose of estimating these temperatures, an analysis was made of the clutch system, and a solution was developed from the partial differential equations of heat conduction with appropriate boundary conditions. The solution thus obtained was verified experimentally.
There were several important conclusions to this study. The maximum temperature rise occurs somewhat earlier than the end of the lockup time. The interface temperature rise increases as the lockup time decreases for a fixed amount of energy input. The ratio of heat flux entering the reaction plate to that entering the composite plate is not constant, as has been assumed by others. The heat absorbed by the fluid outside the clutch pack is negligible during the short lockup time. Temperature rises for some typical cases are computed.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Control of Band/Drum Interface Temperature in Automatic Transmissions and the Impact Upon Friction System Durability

902147

View Details

TECHNICAL PAPER

Optimizing Automatic Transmission Clutch Lining Load Distribution Using Finite Element Analysis

900559

View Details

TECHNICAL PAPER

SURFACE TEMPERATURES AND FRICTION IN LUBRICATED CLUTCHES

630028

View Details

X