1989-09-01

Closed-System, High-Flux Evaporative Spray Cooling 892316

Investigations into the feasibility of high-heat flux, evaporative spray cooling in a single-component, closed-system are reported. A spray cooling heat exchanger was designed, manufactured, and tested. Three specific areas were investigated. These were: (1) the effects of noncondensable gas on the heat transfer. (2) the maximum heat flux and heat transfer coefficient. (3) the effects of variation in spray characteristics.
The experiments conducted in the saturated, single-component, closed-system demonstrated heat removal rates in excess of 1000 W/cm2 with only a 27 ºc superheat. It was shown that removing the air from the system had little effect on the evaporation heat transfer efficiency. However, as expected, the condensation heat transfer efficiency improved greatly when the air was removed.
The effects of nozzle size, flow rate, and average droplet diameter and velocity are explained through analysis of the experimental data. The measurements of the spray characteristics lend insight into the mechanisms responsible for causing critical heat flux.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Design and Development of a Hydrophilic-Coated Evaporator System for Heat Rejection in Space

2001-01-2153

View Details

TECHNICAL PAPER

Heat and Mass Transfer Considerations of Moist Air

2000-01-0576

View Details

STANDARD

Procedure for Measuring System COP [Coefficient of Performance] of a Mobile Air Conditioning System on a Test Bench

J2765_201707

View Details

X