1993-04-01

Nucleate Boiling Engine Cooling System - Vehicle Study 931132

A fundamental vehicle study for a new engine cooling system, the so called NUCLEATE BOILING ENGINE COOLING SYSTEM, has been tested under real and critical conditions in a climate controlled wind-tunnel. Using this cooling system requires a profound knowledge of the cooling circuit and all cooling components such as:
condenser, waterpump, liquid/vapor-separator, expansion tank, fan control unit. After preliminary experimental and theoretical studies, two types of cooling circuits were realized and tested in a car:
  • Completely filled nucleate boiling cooling system
  • Partially filled nucleate boiling cooling system
Both types of circuits were sealed systems. This meant there was no evaporation or loss of liquid into the environment.
By using the nucleate boiling cooling system, the heat of the cylinder head was dissipated while the boiling process change of liquid phase to vapor at constant boiling temperature. The considerable heat transfer coefficient during boiling in the engine and condensation in the condenser allows a low liquid flow rate. Furthermore it is possible to get a uniform temperature distribution in the cylinder head. With both types of circuits all the engine cooling requirements can be fulfilled. However, there are some important advantages for the completely filled nucleate boiling cooling circuit.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Incorporating Nucleate Boiling in a Precision Cooling Strategy for Combustion Engines

971791

View Details

TECHNICAL PAPER

New Concept of Engine Cooling System (Newcool)

971775

View Details

TECHNICAL PAPER

Optimization of Nucleate Boiling Engine Cooling Systems - Condenser Study

910642

View Details