1995-11-01

Biofidelity and Injury Assessment in Eurosid I and Biosid 952731

Side impact pendulum tests were conducted on Eurosid I and Biosid to assess the biofidelity of the thorax, abdomen and pelvis, and determine injury tolerance levels. Each body region was impacted at 4.5, 6.7, and 9.4 m/s using test conditions which duplicate cadaver impacts with a 15 cm flat-circular 23.4 kg rigid mass. The cadaver database establishes human response and injury risk assessment in side impact.
Both dummies showed better biofidelity when compared to the lowest-speed cadaver response corridor. At higher speeds, peak force was substantially higher. The average peak contact force was 1.56 times greater in Biosid and 2.19 times greater in Eurosid 1 than the average cadaver response. The Eurosid I abdomen had the most dissimilar response and lacks biofidelity. Overall, Biosid has better biofidelity than Eurosid I with an average 21% lower peak load and a closer match to the duration of cadaver impact responses for the three body regions.
There was a significant correlation between cadaver and dummy responses in similar tests; so, within the limitations discussed, injury risk can be assessed in the dummies. Eurosid I chest deflection was not sufficient to prevent bottoming in high-speed tests. However, peak VC occurs before rib bottoming and enables chest injury assessment for all of the pendulum impacts.
Based on a 50% risk of AIS 3+ chest injury in a 45 year old cadaver, Eurosid I tolerances are D = 52 mm and VC = 1.17 m/s. For pelvic fracture, the tolerances are F pubic 7.1 kN and GS3-Y = 100 g. Based on a 25% risk of AIS 4+ chest injury, Biosid tolerances are D = 64 mm and VC = 1.37 m/s. For pelvic fracture, Fpubic = 3.6 kN and GS3-Y = 100 g. The research establishes a technical basis for injury tolerance levels in Eurosid I and Biosid.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Comparison of Thoracic Injury Risk in Frontal Car Crashes for Occupant Restrained without Belt Load Limiters and Those Restrained with 6 kN and 4 kN Belt Load Limiters

2001-22-0009

View Details

TECHNICAL PAPER

Assessing the Safety Performance of Occupant Restraint Systems

902328

View Details

TECHNICAL PAPER

ES2 Neck Injury Assessment Reference Values for Lateral Loading in Side Facing Seats

2009-22-0015

View Details

X