Comparison of the Thor, Hybrid Iii and Cadaver Lower Leg Dynamic Responses in Dorsiflexion 99SC10

As of toady, statutory crash test dummies take neither bracing nor passive muscular effect into account in the lower limb area. The influence of the lower extremity musculature is however arising as a major concern for the study of front seat occupant protection.
The lower extremity prototype of the THOR dummy, including a model of the human plantarflexion actuator passive response, was tested in dynamic dorsiflexion. A dynamic test series was performed on Thor-Lx under test conditions similar to those used by Portier et al., 1996, on cadavers and Hybrid III dummy.
The test setup imposed a dynamic dorsiflexion to the foot by means of a load exerted under the ball of the foot with no impact velocity.
The Thor-Lx and Hill responses are compared to cadaver responses. It is important to note that as of today there are no data available to demonstrate that the passive resistance of the cadaver is equivalent to resistance of a tensed human.
The results clearly show a greater similarity between Thor-Lx and cadaver responses than between cadaver and Hybrid III, which does not simulate muscle resistance applied by the Achilles tendon. The amount of muscle tension that should be incorporated into dummy leg designs to simulate the tensed and relaxed human remains to be identified. It is obvious however that only passive muscle resistance was present in the cadavers used in this study (muscle tone being present only in living subjects).
Based on these tests, some minor improvements are suggested in order to make the prototype more reliable and easier to use.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Methodology for Measuring Tibial and Fibular Loads in a Cadaver

2002-01-0682

View Details

TECHNICAL PAPER

Development and Design of Thor-Lx: The Thor Lower Extremity

99SC09

View Details

TECHNICAL PAPER

Analysis of upper extremity response under side air bag loading

2001-06-0016

View Details

X